Fluidyne-control-systems 6600 Series P. D. Flowmeters Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Fluidyne-control-systems 6600 Series P. D. Flowmeters. Fluidyne Control Systems 6600 Series P. D. Flowmeters User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
100
% ACCURACY
0 10
% FLOW RATE
20 30 40 50 60 70 80 90
0
-0.5
+0.5
0.1
% FLOW RATE
100 20 30 40 50 10060 70 80 90
Pr.Drop Kg/Cm
0.2
0.3
0.4
0.5
Fluidyne Control Systems (P) Ltd.
S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,
Pune-411 023. India
Tel.: 020-25290504, 25290870 Fax: 020-25292773
Series 6600 : P. D. Flowmeters
For Fuels / Solvents / Chemicals / Lube Oils.
www.fluidyne.co.in
Rate + Totaliser
Remote W/P Indicator
Rate + Totaliser
+ 20 mA Analog Output
or Rs485 Serial Output
Remote W/P Indicator
Specifications
Features
Introduction
2
oo
Meter + W/P
Pulse Transmitter
Meter + FLP
Pulse Transmitter
Applications
Meter + Integral
W/P Indicator
Meter + Integral
FLP Indicator
Test Fluid : Disel
TYPICAL ACCURACY
CHARACRERISTICS
Test Fluid : Disel
TYPICAL PRES.
DROP CHARACRERISTICS
The Fluidyne Positive Displacement Flowmeters are based on
the time tested Oscillating Piston design. A single moving
component in the assembly ensures extremely reliable operation
for long period of operation. Use of state of the art solid state
magnetic sensor, ultra low powered electronic sensor provides
for all the simplicity of a mechanical P.D. Flowmeter and the
reliability of electronic sensing and read outs.
Flowmeter Size Operating Flow Range
NB LPH
DN06 3-60
DN15 60-600
DN20 150-1500
DN25 240-2400
DN40 600-6000
DN50 1200-12000
DN80 2400-24000
Size Vs Flowrange Table
: DN 06 / 15 / 20 / 25 / 40 / 50 / 80
: 3.0 - 24000 LPH
: ± 0.5% of reading
: ± 0.1% of reading
: 10 Kg / Cm Max.
: 150 C
: 150 Micron SS Mesh Reusable Type
: a) Self Powered Totaliser
b) Rate Indicator Totaliser
c) Rate Indicator Totaliser + 4 - 20 mA output
d) Rate Indicator Totaliser + RS485 Serial Output
: Flange : ANSI / BS / DIN
: Screw : BSP / NPT Female Threads
Wetted Parts : Aluminium / SS 316 / PVC
: Piston : PEEK / PVC
Seals : BUNA N / Viton / EPDM / Teflon
Size
Flow Accuracy
Accuracy
Repeatability
Operating Pressure
Operating Temperature
Filter Mesh Size
Read Out Option
End Connections
Material of construction
Wide operating flow range of 3.0 to 24000 LPH
Guranteed accuracy of +/- 0.5% of reading
Low pressure drop allows gravity head operation.
0
Operation at maximum 150 C temperature possible.
Self powered electronics ensures fit and forget operation.
Choice of weatherproof and flameproof electronic enclosures.
Built in high capacity reusable wire mesh filter.
S.S and Plastics builds to suit corrosive liquids.
S.S. and Plastics builds to suit corrosive liquids.
·
·
·
·
·
·
·
·
·
Vue de la page 0
1

Résumé du contenu

Page 1 - P. D. Flowmeters

100% ACCURACY0 10% FLOW RATE20 30 40 50 60 70 80 900-0.5+0.50.1% FLOW RATE100 20 30 40 50 10060 70 80 90Pr.Drop Kg/Cm0.20.30.40.5Fluidyne Control Syst

Commentaires sur ces manuels

Pas de commentaire