Fluidyne Control Systems (P) Ltd.
S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,
Pune-411 023. India
Tel.: 020-25290504, 25290870 Fax: 020-25292773
Series 6610 : PC Compatible
P. D. Flowmetering System
For Fuels/ Solvents / Water / Chemicals / Industrial Liquids
www.fluidyne.co.in
:
Fuel Consumption Report
FuelLog
Monthly Consumption Report
MONTH
JULY YEAR 2006 .
METER 4 . SERVICE DIESEL
LINE TEST CELL 01 USER R & D
Consumption
(Litres)
150.3
251.4
25.6
110.7
32
24.7
85.8
92.3
28.5
62.3
124.7
55
988.3
1043.3
680.5
772.8
801.3
863.6
427.3
538
570
594.7
Closing
(Litres)
150.3
401.7
9/7/2006
10/7/2006
11/7/2006
12/7/2006
Date
1/7/2006
2/7/2006
7/7/2006
8/7/2006
3/7/2006
4/7/2006
5/7/2006
6/7/2006
Typical Network
Diesel
Dispenser
Genset Fuel
Consumption
Monitor
Furnace Oil
Flowmeter
Flowmeter Used
Measurement Range
Measurement Accuracy
Liquid Compatibility
Serial Data Transmission
Software Utility
Database
PC OS Compatibility
Max. No of Meter Network
Report Generated
Report Format
Fluidyne Series 6600 P. D. Flowmeters
3-24000LPH
± 0.5% of reading
Fuels/Lubes/Solvent/Water/Corrosive Chemical
Hardware Protocol : RS485
Software Protocol : Proprietory
‘FuelLog’ in Visual C++
Disc Space Occupied : 1MB
MS Access
Window 98 to Window XP
16
Daily / Monthly / Yearly Usage
EXCEL
Specifications
RS485-RS232
Convertor
PC
PC
Series 6601
P.D.Flow Transmitter
RS485-RS232
Convertor
:
:
:
:
:
:
:
:
:
:
:
Introduction
FuelLog is an innovative combinations of precision flow
measurement technology with state of the art electronic serial
communication transmitter and software utility compatible with all
PCs It provides real time data logging directly on the PC with the
added benefit of automatic generation of daily and monthly usage
reports making all display based flow meter technology completely
obsolete. Networking of multiple Flowmeters with one single PC
actualy reduces installation cost compared to standard Flowmeters
while providing unparallelled reliability, accuracy and ease of use.
Features
·
·
·
·
·
·
·
·
Typical Industrial Applications
No manual logging
Direct PC interface
RS485 Serial Com up to 1KM distance
One PC to 16 Flowmeters network
PC software utility provided
Day / Month / Year wise usage reports in Excel
Local Display optional
MODBUS RTU output optional
·
·
·
·
·
·
·
·
Tanker Unloading
Genset Fuel Consumption
Boiler / Furnace Fuel consumption
Vehicle / Forklift refueling
Lube Oil / Solvent issues
Test cell Fuel Consumption
Assembly Line Fuel / Oil Dispensing
Solvent / Chemical Transfer to reactors
Flowmeter Size Operating Flow Range
NB LPH
DN06 3-60
DN15 60-600
DN20 150-1500
DN25 240-2400
DN40 600-6000
DN50 1200-12000
DN80 2400-24000
Size Vs Flowrange Table